Apply waterproofing membrane
Waterproofing conduit membrane for the diverter
Waterproofing conduit membrane for the shower head
Waterproofing conduit membrane for the Control Dial
Waterproofing conduit membrane for the pipe to the Orbital Shower Core
Waterproofing membrane shall be applied around 5 penetrations on the floor and wall.
Remove the protective cover from the drain unit.
Roughen the metal surface of the drain unit and clean it with rubbing alcohol or similar.
Notice
To achieve optimal bonding, all surfaces should be clean and free of adhesion reducing substances (e.g. dust, acid, grease).
Apply waterproofing glue to the drain unit's metal flange.
Spread the waterproofing glue with a fine-toothed glue spreader or brush.
Apply liquid membrane to the floor- and wall surface, which the drain waterproofing membrane is going to cover.
Apply the drain waterproofing membrane around the drain unit. When mounting the drain waterproofing membrane, make sure to cover both the floor and the wall. Firmly apply pressure and remove air pockets using a smoothing tool. Make sure no blisters or creases occur.
Carefully mount waterproofing membrane and overlap by at least 50 mm. Close the joints with adhesive.
Apply waterproofing conduit membrane according to the chosen manufacturer to seal the conduits coming out of the wall.
Make sure remaining surfaces are being waterproofed according to chosen waterproofing membrane manufacturer and industry rules.