Prepare shower area
Frame the shower area.
Mark the floor level where the waterproofing will be connected to the drain unit flange. This mark will be used as measurement "X" in the installation process to ensure that there is enough space for the drain unit.
Install noggings.
Caution
It is crucial that all nogging pieces are level and set according to recommended measurements to avoid misalignment in the shower installation.
Frame the area where the Wall Box will be installed.
Make sure the Wall Box will fit inside the wall. See chapter Kit measurements for correct measurements.
Notice
Adjust slot in studs and wall covering depending on hand shower and Control Dial placement.
Figure 33. Only valid for Orbital Audio installationApply wall covering according to industry rules.
The hole is centered in the shower area.