Skip to main content

Installation

Installing the diverter and hand shower
  1. Cut the conduits to a minimum of 6 mm and a max of 9 mm outside of the tile surface.

    220125_Install_Bypass_block_Cut_sleeve.eps
  2. Push the PEX pipes in until it stops, and cut them 25 mm outside the tile surface. Deburr and calibrate the pipes.

    Caution

    It’s important that the PEX hoses are pushed in all the way to ‘stop’ before cutting.

    220131_Install_cc60_cut_18_millimeter_length.eps
  3. Measure and mark the hole positions for the diverter.

    220128_Panel_cc60_assembly.eps
  4. Mark hole positions for the hand shower holder.

    210421_Install_Diverter_mark_drill_holes_millimeter.eps
  5. Drill four holes (6 mm) in marked locations.

    Caution

    • Only drill through the tile itself.

    • Seal drill holes in accordance with applicable industry standards. See section Seal mountings in wet zone for instructions.

    220131_Install_cc60_drill_holes.eps
  6. Mount the diverter wall plate.

    Caution

    Use 2x included screw, choose screw according to wall thickness.

    220131_Install_cc60.eps

    x2

    TX25 stainless steel screw

    x1

    Twin washer

  7. Secure the diverter body to the diverter wall plate using an Allen key (3mm).

    220201_Install_cc60_o-ring.eps
  8. Install the hand shower to the diverter.

    220202_Install_cc60_hand_shower_cable.eps