Skip to main content

Orbital Service Handbook

14. Filter & UV

This instruction shows how to swap the Filter and UV kit in a Hatch Panel installation, where the Core is placed in the shower area. Follow the instructions in detail, and don't hesitate to reach out if you have any questions - support@orbital-systems.com.

Use the kit below to swap the Filter and UV-kit.

Table 22. 1-04-0180 - Maintenance kit 2:

Filter Capsule

UV lamp

Quartz jacket kit



Dismantle Filter & UV

  1. Turn off the power.

    231213-Turn_on_power.eps
  2. Open the door.

    231208-Open_Panel.eps
  3. Open the filter door and release the filter holder.

    240312-Open_Core_and_Filter_Hatch.eps
  4. Remove the old Filter Capsule

    240312-Remove_Filter.eps
  5. Unscrew the UV protection cover.

    240313-Remove_UV_protective_shield.eps
  6. Turn the plug counterclockwise to release the UV lamp.

    240313-Remove_UV_contact.eps
  7. Disconnect the lamp and put it aside.

    240417_1-02-0045_R3_change_UV_lamp_1.eps
  8. Turn the bayonet lock counterclockwise to release the quartz glass.

    240417_R3_clean_glass_2.eps

Install Filter & UV-kit

  1. Change the quartz glass and tighten the bayonet lock.

    Caution

    Make sure the o-ring is undamaged and in good condition.

    240313-Insert_new_UV_glass_and_lock.eps
  2. Connect the new UV lamp, turn the plug clockwise to lock.

    Caution

    Make sure that the lamp goes all the way into the socket.

    240418_1-02-0045_R3_change_UV_lamp_and_Q_glass.eps
  3. Reinstall the UV protection cover.

    240418_change_uv_lamp_reassemble_R3.eps
  4. Insert a new Filter Capsule.

    Caution

    Ensure that the Filter Capsule is correctly inserted to avoid leakage.

    240312-Insert_Filter.eps
  5. Close the filter holder and the filter hatch.

    240312-Close_filter_hatch_and_Core.eps
  6. Close the door to the Wall Box.

    240903-Close_Panel.eps
  7. Turn on the power. It takes about 1 minute for the Core to start up.

    231213-Turn_on_power.eps
  8. Start the shower and set the temperature to 28°C. The shower should start recycling (showing countdown on Control Dial) within 5 minutes without increased noise level.

    231120_instruction_-_start_and_stop_adjust_temperature.eps
  9. Turn off the shower.

    231211_stop.eps
  10. Complete and submit the service report (found in the service request).

  11. Recycle the replaced components. 240516-Recycling.eps