14. Filter & UV
This instruction shows how to swap the Filter and UV kit in a Hatch Panel installation, where the Core is placed in the shower area. Follow the instructions in detail, and don't hesitate to reach out if you have any questions - support@orbital-systems.com.
Use the kit below to swap the Filter and UV-kit.
Filter Capsule |
UV lamp |
Quartz jacket kit |
Dismantle Filter & UV
Turn off the power.
Open the door.
Open the filter door and release the filter holder.
Remove the old Filter Capsule
Unscrew the UV protection cover.
Turn the plug counterclockwise to release the UV lamp.
Disconnect the lamp and put it aside.
Turn the bayonet lock counterclockwise to release the quartz glass.
Install Filter & UV-kit
Change the quartz glass and tighten the bayonet lock.
Caution
Make sure the o-ring is undamaged and in good condition.
Connect the new UV lamp, turn the plug clockwise to lock.
Caution
Make sure that the lamp goes all the way into the socket.
Reinstall the UV protection cover.
Insert a new Filter Capsule.
Caution
Ensure that the Filter Capsule is correctly inserted to avoid leakage.
Close the filter holder and the filter hatch.
Close the door to the Wall Box.
Turn on the power. It takes about 1 minute for the Core to start up.
Start the shower and set the temperature to 28°C. The shower should start recycling (showing countdown on Control Dial) within 5 minutes without increased noise level.
Turn off the shower.
Complete and submit the service report (found in the service request).
Recycle the replaced components.