Skip to main content

Orbital Service Handbook

7. Hand shower

This instruction shows how to swap the hand shower. Follow the instructions in detail, and don't hesitate to reach out if you have any questions - support@orbital-systems.com.

Use the following kit to swap the hand shower. This kit is available in several color variants.

Table 34. 1-04-0177 - Swap hand shower kit:

Hand shower with hose

Hand shower holder - wall plate

Hand shower holder - cover

2 mm hex key tool (Allen key)

M4x8 Set screw

Screw ST4.2 x 50mm A2, TX 20

Screw ST4.2 x 45mm A2, TX 20

Screw ST4.2 x 38mm A2, TX 20



Dismantle hand shower

  1. Disconnect the hand shower from the diverter.

    240308-Remove_Hand_Shower.eps
  2. Unscrew the hand shower holder. The screw is on the underside.

    240312_Remove_hand_shower_holder_1.eps
  3. Loosen the sleeve.

    240312_Remove_hand_shower_holder_2.eps
  4. Screw down the wall plate.

    Note

    If the wall plate is undamaged, it should be reused and does not need to be dismantled, unless otherwise specified in the work order. This step and steps 1-2 under "Installing a new hand shower" therefore only apply when replacing the wall plate.

    240312_Install_hand_shower_holder.eps

Install hand shower

Steps 1-2 only apply if the wall bracket is to be replaced.

  1. Clean the surface under the wall plate.

    240312_Clean_under_hand_shower_holder.eps
  2. Install the new wall bracket.

    Caution

    Fill the holes with wet room silicone. The bracket must be mounted horizontally.

    240312_Install_hand_shower_holder.eps
  3. Mount the hand shower holder on the wall bracket. The screw must not be overtightened.

    240426_Install_hand_shower_holder.eps
  4. Install the hand shower hose.

    Caution

    Make sure the gasket is in good condition and has no damage.

    220202_Install_cc60_hand_shower_cable.eps
  5. Start the shower and switch to hand shower. Ensure that the connection is leak-free.

    240312_Operating_hand_shower.eps
  6. Turn off the shower.

    230621_instruction_-_start_and_stop_shower.eps
  7. Complete and submit the service report (found in the service request).

  8. Recycle the parts and components that should not be reused. 240516-Recycling.eps