  • . Installation scenario
. Installation possibilities
  • The Core (shower unit) can be placed within three meters of the shower area.

  • 241030-Hatch_LK-Installation-Possible-Placement-1.eps
  • There can be a maximum of three bends (6x45°).

  • 241030-Hatch_LK-Installation-Possible-Placement-2.eps
  • The stud depth in the shower area must be a minimum of 90 mm and at the Core a minimum of 145 mm.

  • 241030-Hatch_LK-Installation-Possible-Placement-3.eps
. Installation limitations
  • The Core cannot be placed more than three meters from the shower area.

  • 241030-Hatch_LK-Installation-Not-Possible-Placement-1.eps
  • There cannot be more than three bends (6x45°) between the shower area and the Core.

  • 241030-Hatch_LK-Installation-Not-Possible-Placement-2.eps
  • The pipe routing cannot go around a door.

  • 241030-Hatch_LK-Installation-Not-Possible-Placement-3.eps
. Product measurements

All measurements are given in millimetres (mm).

  • 240607-Hatch_Product_Measurements.eps
  • * The supplied water trap meets the European standard EN1253-1 and can be used for buildings of any height. If the building has one ground floor and up to three floors above it, you can use a water trap designed for shorter buildings that follow standards EN1253-6 and EN1253-7. Good options include the Unidrain 1417 or Unidrain 1415 models.