Skip to main content

Orbital Tap Installation

Technical specification

General performance

Savings rate:

Up to 100% water savings of water used in sink

Size and weight

Tank:

440 x 270 x 65 mm, 1.2 kg

Pump:

197 x 296 x 140 mm, 3.5 kg

AC/DC power supply:

152 x 63 x 30 mm, 420 g

Water supply

Incoming Cold water:

Recommended flow: 5-8 l/min

Recommended incoming water pressure: 2-5 bar

Maximum working pressure: PN10

Water connections (Tank and Pump):

G 1/2 threads (ISO 228/1-G 1/2” external threads) and G 3/8 threads (ISO 228/1-G 3/8” external threads)

Water hardness:

3°dH-14°dH.

If the local water hardness on the installation site is more than 14dH it is recommended to install a water softener.

Recommended power supply

100-240V, 50/60Hz, 2.5A, 120W

Power consumption:

Tank and Pump unit; active mode: nominal 25W, max. 70W; standby mode: 0.21W

Installation area

Full system:

All components are wall mounted: behind commode, below wash basin or up to 3 m from the wash basin. The top inlet in the Tank needs to be placed at a lower point than the outlet from the wash basin. The Pump needs to be placed within 6 m from the toilet cistern.

Maintenance

Cleaning tablet:

Add in the sink at regular intervals to both clean the product and get a fresher bathroom experience. The frequency depends on usage and preference.

Fresh Mesh:

Cleaned by hand, in a dishwasher, or replaced when needed. The frequency depends on usage; typically once per month. It’s important that the Fresh Mesh is not emptied and cleaned in the wash basin.