Installing the diverter and hand shower
Cut conduit minimum 6 mm, max 9 mm outside of tile surface.
Mark hole positions for the hand shower holder as well.
Drill 4 holes (6 mm) in marked locations.
Caution
Only drill through the tile itself.
Seal drill holes according to industry rules. See section Seal mountings in wet zone for instruction.
Caution
It’s important that the PEX hoses are pushed in all the way to ‘stop’ before cutting to the correct length of 25 mm.
Make sure the pipe is cut straight and avoid too many degrees. A PEX pipe bevel tool is recommended to avoid damage to o-rings.
Caution
Use 2x included screw, choose screw according to wall thickness.
x2
TX25 stainless steel screw
x1
Twin washer
Use an allen key, 3mm, to secure the diverter body to the diverter wall plate.